ÈÈÃŹؼü´Ê£º
ÈÈÃŹؼü´Ê£º
²úÆ·Ãû³Æ£º | DMF-ZÖ±½Çʽµç´ÅÂö³å·§ |
²úÆ·Ðͺţº | |
²úÆ·¹æ¸ñ£º | |
ÊäÈëµçѹ£º | |
·ç¡¡¡¡Á¿£º | |
¾» »¯ ÂÊ£º | |
Ó¦ÓÃÁìÓò£º | |
ÔÚÏ߿ͷþ£º | µãÎÒÁªÏµ |
·þÎñµç»°£º | 0317-8356829 |
²úÆ·¸ÅÊö
µç´ÅÂö³å·§×¨Îª³ý³¾É豸µÄÓ¦ÓöøÉè¼Æ£¬¾ßÓиßÁ÷Á¿¡¢³¤ÊÙÃü¡¢Ë²¼ä¿ª¹ØµÄ·§ÃÅ£¬Óɵç´ÅÏȵ¼¿ØÖÆÆä¿ªÍ¨ºÍ¹Ø±Õ£¬ÓÉÓÚÏȽøµÄÉè¼Æ£¬Ê¹·§ÃžßÓÐÁ¼ºÃµÄÁ÷ÌåÐÔ£¬²ÉÓö¥¼¶¶¡ÇçÏð½ºÄ¤Æ¬£¬¹Ê¶ø¾ßÓÐѹÁ¦ËðʧµÍ£¬ÎÒ˾¶àÄêÑз¢¾ÑéʹµÃ²úÆ·¸ü¼Ó³ÉÊ죬±£Ö¤Á˵ç´ÅÂö³å·§µÃµ½Âö³åµçÐźÅʱ¿ìËÙ¿ªÆôºÍÍê³ÉÂö³åºóµÄѸËٹرա£
¸ß´¿¶ÈÂÁºÏ½ðѹÖý·§Ì壬¶¥¼¶ÌØÊâ¼ÐÎï×é³ÉµÄµç´ÅÂö³å·§Ä¤Æ¬£¬Ê¹µÃĤƬ¾ßÓм«¸ßµÄÀÉìÇ¿¶È¡¢¿¹ÀÏ»¯ÐԺͽϵ͵ÄÄ¥ËðÁ¿£¬Ê¹µÃÎÒ˾µç´ÅÂö³å·§Åç´µÊÙÃü¸ßÓÚ100Íò´Î»òÈýÖÁÎåÄêʹÓò»Ë𻵡£
µç´ÅÂö³å·§ÏßȦ²ÉÓøßÓÚ¹ú±ê¼¶¾øÔµ×¢ÉäÔÚ·À»¤µÈ¼¶ÎªIP65È«¹à·â£¬È«ÍÆá°üÏߣ¬È¦Êý¸ßÓÚO±ê×¼£¬±£Ö¤µç´ÅÂö³å·§600Íò´ÎͨµçÎüºÏ²»Ë𻵣¬µç´ÅÏßȦ¿ÉÒÔÔÚÂö³å·§Ð¾ÉÏ360°Ðýת£¬½ÓÏߺпÉÒÔ4 x 90°Ðýת°²×°£¬¿É·ÀÖ¹±©Â¶ÔÚ¶ÌìʱÓêË®½øÈ룬¼«´ó·½±ãÁ˲»Í¬½Ç¶È°²×°¡£
²úÆ·½éÉÜ
DMF-ZÐ͵ç´ÅÂö³å·§ÊäÈë¿ÚÓëÊä³ö¿Ú¼Ð½ÇΪ90°³ÆÖ®ÎªÖ±½Ç·§£¬ÆäÊäÈë¡¢Êä³ö¿ÚΪÄÚÂÝÎÆ£¬·Ö±ðÓë·ÖÆøÏä(Æø°ü)ÉϵĶ̹ܻòÅç´µÂÝÎÆ¹ÜÁ¬½Ó£¬°²×°·½±ã¡¢ÆøÁ÷ͨ³©£¬ÄÜÌṩÀíÏëµÄÇå»ÒÆøÂö³å£¬ÊÊÓÃÓÚ¸÷ÖÖ¹ýÂ˵¥ÔªµÄÇå»Ò¡£
ʹÓü¼ÊõÖ¸±ê
¹¤×÷ѹÁ¦Operating pressure | 0.2~0.6MPa |
¹¤×÷½éÖÊWorking medium | Çå½à¿ÕÆøClean air |
µçѹVoltage | DC24V AC110V AC220V(Ê¿10%) |
µçÁ÷Current | 1A 0.46A 0.23A |
ζȵȼ¶Temperature level | 1.³£ÎÂ-25¡æ~80¡æ(-13¨H~176¨H) 2.¸ßÎÂ-25¡æ~23¡æ(-13¨H~446¨H) |
¿ÕÆøÏà¶Ôʪ¶ÈRelative humidity of air | ¿ÕÆøµÄÏà¶Ôʪ¶È≤85% |
·À»¤µÈ¼¶Degree of protection | IP65 |
ĤƬÊÙÃüDiaphragm life | ¸ßÓÚ100Íò´Î£¬»ò3-5Äê |
±¸×¢£º1.µç´ÅÂö³å·§¾ù¿É×°ÏûÒôÆ÷¡£2.µç´ÅÂö³å·§¿ÉÑ¡ÅäÓÐÈÏÖ¤µÄ·À±¬ÏßȦ¡£
²ÄÖÊ˵Ã÷
·§ÌåBody | ADC12ÂÁºÏ½ð ADC12 aluminum alloy |
¿¨»ÉClamp spring | 304²»Ðâ¸Ö 304stainless steel |
Ïȵ¼×é¼þPilot component | 430FR²»Ðâ¸ÖµÈ²ÄÁÏ 430FR stainless steel,etc |
ĤƬDiaphragm | ¶¡¾¦Ïð½º/·úÏð½ºNitrite rubber/fluororubber(high-temperature valve) |
µ¯»ÉSpring | 304²»Ðâ¸Ö 304 stainless steel |
½ô¹ÌÌåFastener | 302²»Ðâ¸Ö 302 stainless steel |
ĤƬ²ÉÓö¥¼¶³ÉƷĤƬ£¬ÖÊÁ¿Óë½ø¿ÚæÇÃÀ£¬³¬Ç¿µÄÀÉìÐÔ£¬Ã¿Æ¬Ä¤Æ¬¶¼¾¹ýÑϸñ¼ì²âºó·½¿É½øÈë×°ÅäÏß¡¢×°Åäºóÿһ¸ö³ÉÆ··§½øÐмì²â£¬¸÷ÏîÖ¸±êÈ«²¿ºÏ¸ñ·½¿É³ö³§¡£
Ðͺź¬Òå
°²×°Ê¾Òâͼ
¹æ¸ñ³ß´ç
°²×°·½·¨Ìáʾ
1¡¢µç´ÅÂö³å·§µÄÅç´µÆøÔ´ÓÉÆøÏä(Æø°ü)Ìṩ£¬·ÖÆøÏäÓз½ÐκÍÔ²ÐζþÖÖ£¬Ô²ÐÎ·ÖÆøÏäÄÍѹÁ¦Ð§¹û½ÏºÃ£¬Ê¹ÓÃÑÍûʽµç´ÅÂö³å·§Ê±£¬·½ÐÎ·ÖÆøÏä°²×°±È½Ï·½±ã¡£
2¡¢·ÖÆøÏäµÄ½ØÃæ»ýºÍ³¤¶È¾ö¶¨´¢ÆøÈÝ»ý£¬ÆäÈÝ»ýÓ¦Âú×ã¸Ã×éÂö³å·§Ã¿´ÎÅç´µºó£¬ÏäÄÚÊ£ÓàѹÁ¦²»µÍÓÚÅ紵ǰѹÁ¦µÄ50%£¬½øÆø¹ÜÄÚ¾¶¾ö¶¨Ïò·ÖÆøÏä³äÆøËÙ¶È£¬ÆäËÙ¶ÈÓ¦Âú×ã¸Ã×éÂö³å·§Ã¿´ÎÅç´µºó10sÄÚʹÏäÄÚÆøÌå»Ö¸´ÖÁÅ紵ǰѹÁ¦¡£
3¡¢Âö³å·§Ó¦°²×°ÔÚ·ÖÆøÏäµÄÉϲ¿»ò²àÃæ£¬°²×°²àÃæÊ±Âö³å·§ÊäÈë¶ËÖÐÐIJ»Ó¦µÍÓÚ·ÖÆøÏä²àÃæÖÐÐÄÏßÒÔÏ£¬Âö³å·§²»¿É°²×°ÔÚ·ÖÆøÏäµ×²¿£¬Í¬Ê±Âö³å·§Êä³ö¶ËÓ¦°²×°´¦ÓÚˮƽ»òÏòÏÂλÖ㬲»¿É°²×°ÏòÉÏλÖá£
4¡¢Åç´µ¹ÜµÄÅç´µ¿×ӦСÓÚ18×óÓÒ£¬¿ª¿×Ϊ:8-32mm(ԶС½ü´ó)£¬Åç´µ¹ÜÀë²¼´ü¿Ú200-400ΪÒË¡£
µç´ÅÂö³å·§³£¼ûÎÊÌâ
ʹÓý׶ΠStage of use |
¹ÊÕÏÏÖÏó Fault |
ÔÒò·ÖÎö Cause analysis |
Åųý·½·¨ Eliminating method |
°²×°µ÷ÊÔÖÐ Installation and Commissioning |
ËùÓз§ÎÞ·¨´ò¿ª£¬µ«Ïȵ¼²¿·Ö Óж¯×÷ Not all the valves can be opened,but the pilot part is running |
¼ì²éÆø°üѹÁ¦ÊÇ·ñ¹ýµÍ Check whether the air tank pressure is too low |
ÅŲéÂ©Æø Check and prevent air leakage |
ijЩ·§²»¹¤×÷£¬ÆäËû·§Õý³£ Some valves cannot run while others can |
¼ì²é·§µÄÏß·Á¬½Ó¼°ÏßȦ Check the line connections and sole-noids of the valves |
¸ü»»Åä¼þ Replace relevant parts |
|
ËùÓз§ÎÞ·¨¹Ø±Õ£¬ÓÐÂ©Æø£¬ Æø°üѹÁ¦ÎÞ·¨½¨Á¢ Not all the valves can be closed;there is air leakage; the air tank pressure cannot be established |
·§µÄ½øÆø¿ÚÓëÅç´µ¿ÚÏà·´°²×° The air inlets and air outlets of the valves are reversely Installed |
ÖØÐ°²×° Install the valves again |
|
ijЩ·§ÎÞ·¨¹Ø±Õ£¬ÓÐÂ©Æø Some valves cannot be closed, there is air leakage |
ÓÐÔÓÖÊÎü¸½ÔÚĤƬÉÏ£¬¶¯ÌúоÓп¨ËÀÏÖÏó There are foreign matters on the diaphragms; the armatures are seized |
Çå½àĤƬ£¬¼ì²éĤƬÊÇ·ñÍêÕû£¬ ¼ì²é¶¯Ìúо¼°ÆøÈû Clean the diaphragms and check whether they are complete; check the armatures and the air plugs |
|
ʹÓùý³ÌÖÐ Use |
·§¹Ø±Õ»ºÂý Valve closing is slow |
ĤƬ½ÚÁ÷¿×Êܶ The diaphragm orifices are blocked |
ÊèͨĤƬ½ÚÁ÷¿× Unblock them |
ijЩ·§Â©Æø£¬Ä¤Æ¬¹Ø²»ËÀ£¬ ·§³£¿ª Some valves leak, they often open,their diaphragms cannot be closed com-pletely |
ÓÐÔÓÖÊÎü¸½ÔÚĤƬÉÏ£¬Ïȵ¼Ë𻵣¬¶¯ÌúоÓп¨ËÀÏÖÏó There are foreign matters on the diaphragms; the pilot parts are dam-aged; the armatures are seized |
Çå½àĤƬ£¬¼ì²éĤƬÊÇ·ñÍêÕû£¬ ¼ì²é¶¯Ìúо¼°ÈûµÈ£¬¼°Ê±¸ü»»Åä¼þ Clean the diaphragms and check whether they are complete; check the armatures and the air plugs; replace relevant parts promptly |
|
ÏßȦ·¢ÈÈ£¬ÉÕ»Ù There is solenoid heating or burning |
³¤Ê±¼äͨµç The valves have been powered on for a very long time |
¼ì²é¿ØÖÆÏµÍ³µÄ¹¤×÷×´¿ö Cheak the operating status of the control system |
|
Óеçѹ£¬µ«·§²»¶¯×÷ There is voltage but the valves cannot run |
ĤƬË𻵻ò½ÚÁ÷¿×Êܶ Diaphragm is damaged, pilot opening is blocked |
¼°Ê±¸ü»»Åä¼þ Replace relevant parts promptly |
|
»·¾³Î¶ȵͣ¬·§ÓÐÂ©Æø»òÎÞ·¨´ò¿ª The ambient temperature is low; the valves leak or cannot be opened |
»·¾³Î¶ȹýµÍ£¬·§ÄÚÓнá±ùÏÖÏó Ambient air temperature too low valve intelnal frozen |
×¢ÒⱣΠKeep a properly high temperature |
ÊÖ»ú£º13832791960
´«Õ棺0317-8356829
ÓÊÏ[email protected]µØÖ·£ººÓ±±Ê¡²´Í·Êв´ÕòÕÅׯ×Ó´å